1,问题描述
客户在监控网络中私自接了一台TP-LINK,TP-LINK频繁的向上游交换机发送TCN BPDU,导致每过一段时间网络监控系统就出现一次蓝屏或者闪断等现象;
S3700版本为:V100R006C05
< BL-1F-SZ-10.17>dis ver
Huawei Versatile Routing Platform Software
VRP (R) software, Version 5.70 (S3700 V100R006C05)
Copyright (C) 2003-2013 HUAWEI TECH CO., LTD
Quidway S3700-28TP-EI-AC Routing Switch uptime is 0 week, 2 days, 2 hours, 55 minutes
EOFEA 0(Master) : uptime is 0 week, 2 days, 2 hours, 54 minutes
128M bytes DDR Memory
16M bytes FLASH
Pcb Version : VER B
Basic BOOTROM Version : 349 Compiled at Mar 15 2013, 11:00:55
Software Version : VRP (R) Software, Version 5.70 (V100R006C05)
图1-1组网拓扑
2,告警信息
监控系统蓝屏、闪断现象截图如下:
3,处理过程
1、监控系统出现蓝屏或者闪断时,立刻查看网络有无异常告警,结果在核心交换机上发现如下告警信息:
<HX-S12708>dis trapbuffer
#Jan 13 2016 13:22:50 HX-S12708 MSTP/4/TCGUARD:OID 1.3.6.1.4.1.2011.5.25.42.4.2.15 The instance received TC message exceeded the threshold will be deferred to deal with at the end of TC protection time. (InstanceID=0)
2、通过上述信息初步怀疑是网络 STP震荡,然后在核心交换机上查看STP-BPDU统计信息如下:
<HX-S12708>display stp tc-bpdu statistics
-------------------------- STP TC/TCN information --------------------------
MSTID Port TC(Send/Receive) TCN(Send/Receive)
0 XGigabitEthernet1/3/0/0 1006/0 0/0
0 XGigabitEthernet1/3/0/1 771/0 0/0
0 GigabitEthernet1/2/1/1 209/0 0/0
0 GigabitEthernet1/2/1/4 218/0 0/0
0 GigabitEthernet1/2/1/5 244/0 0/0
0 GigabitEthernet1/1/1/1 225/0 0/0
0 GigabitEthernet1/1/1/3 212/0 0/0
0 GigabitEthernet1/1/1/4 239/0 0/0
0 GigabitEthernet1/1/1/5 256/0 0/0
0 GigabitEthernet1/1/1/6 218/0 0/0
0 GigabitEthernet1/1/1/7 233/0 0/0
0 XGigabitEthernet2/3/0/0 985/0 0/0
0 XGigabitEthernet2/3/0/1 1022/0 0/0
0 GigabitEthernet2/1/1/0 225/0 0/0
0 GigabitEthernet2/2/1/2 254/0 0/0
0 GigabitEthernet2/2/1/3 218/0 0/0
0 Eth-Trunk1 768/4 0/0
0 Eth-Trunk2 799/3 0/0
0 Eth-Trunk3 819/7 0/0
0 Eth-Trunk4 31/661 0/0
0 Eth-Trunk5 879/10 0/0
0 Eth-Trunk6 907/3 0/0
0 Eth-Trunk7 979/0 0/0
在核心S12708上查看stp拓扑改变,最近一次是10分钟之前,也是从Eth-Trunk4收到的。
<HX-S12708>display stp topology-change
CIST topology change information
Number of topology changes :443
Time since last topology change :0 days 0h:10m:18s
Topology change initiator(notified) :Eth-Trunk4
Topology change last received from :845b-1236-5090
Number of generated topologychange traps : 96
Number of suppressed topologychange traps: 59
3、然后登录到核心S12708的Eth-Trunk4口下接汇聚交换机<BLSZ-HJ-10.7>上查看stp tc-bpdu统计,GigabitEthernet0/0/2口收到的TC报文最多。
<BLSZ-HJ-10.7>display stp tc-bpdu statistics
-------------------------- STP TC/TCN information --------------------------
MSTID Port TC(Send/Receive) TCN(Send/Receive)
0 GigabitEthernet0/0/1 534/0 0/0
0 GigabitEthernet0/0/2 21/324 0/0
0 GigabitEthernet0/0/3 569/0 0/0
0 GigabitEthernet0/0/4 588/0 0/0
0 GigabitEthernet0/0/5 607/0 0/0
0 Eth-Trunk0 463/11 0/0
然后查看stp拓扑变更,最近一次拓扑改变也是GigabitEthernet0/0/2口。
<BLSZ-HJ-10.7>disp stp topology-change
CIST topology change information
Number of topology changes :385
Time since last topology change :0 days 0h:15m:23s
Topology change initiator(notified) :GigabitEthernet0/0/2
Topology change last received from :845b-1235-3ff0
Number of generated topologychange traps : 44
Number of suppressed topologychange traps: 14
4、在汇聚交换机<BLSZ-HJ-10.7>上找到GigabitEthernet0/0/2口下联交换机<BL-1F-SZ-10.17>,在<BL-1F-SZ-10.17>上查看stp tc-bpdu统计,发现Ethernet0/0/8口收到最多的TC报文。
<BL-1F-SZ-10.17>display stp tc-bpdu statistics
-------------------------- STP TC/TCN information --------------------------
MSTID Port TC(Send/Receive) TCN(Send/Receive)
0 Ethernet0/0/8 3362/911 6/256
0 Ethernet0/0/20 2218/0 0/0
0 GigabitEthernet0/0/1 1949/267 0/0
然后再查看stp拓扑变更,最近一次即是<BL-1F-SZ-10.17>的Ethernet0/0/8口。
<BL-1F-SZ-10.17>display stp topology-change
CIST topology change information
Number of topology changes :1435
Time since last topology change :0 days 0h:29m:55s
Topology change initiator(notified) :Ethernet0/0/8
Topology change last received from :0019-e8da-d088
5、查看Ethernet0/0/8口配置,发现是个边缘端口,配置如下:
interface Ethernet0/0/8
port link-type access
port default vlan 15
stp edged-port enable
6、询问客户Ethernet0/0/8下接的是什么设备,经过客户确认是他们最近自己私自接的一台TP-LINK交换机,用于其他业务。然后和客户协调关闭该接口观察一段时间,发现关闭接口后一切正常,问题没有复现。
4,根因
监控网络中私接的一台TP-LINK频繁的向上游交换机发送TCN BPDU,导致每过一段时间网络监控系统就出现一次蓝屏或者闪断等现象
5,解决方案
1.当网络中出现故障,多分析告警信息,通过display trapbuffer,display logbuffer等。
2.规范网络配置,shutdown没有使用的端口,可以有效避免私接交换机导致的网络故障。
6,建议与总结
在原有的网络中新接入其它设备应该充分考虑对现网的影响,有的时候多插了一根网线就会导致网络出现环路,导致网络瘫痪。另外,工程师服务完后一些注意事项应该和客户说明。
随机图文
证据!高空抛物监控与人脸识别监控解决方案
对于现代化小区,高空抛物越来越受重视,相关项目也越来越多,本期我们一起来详细了解高空抛物监控与人脸识别监控的实现方式。 一、高空抛物监控及人胗识别系统方案最全面的智慧物流园区智能化解决方案
智慧园区方案中有个特殊的园区,那就是物流园区,物流园区智能化解决方案如何设计呢?需要考虑哪些特色的智能化系统呢?今天分享一套智慧物流园区解决方案,仅供学习。 借助传统的IT与CT技术,引入云计算,物联网,电子商务等新技术,实现园区的信息化;依托物流信息化平台及物流业务系统,可为园区提供信息服务、交易服务“十四五”期间智慧教育相关政策梳理与解读
智慧城市投建管政策随着国家“十四五”规划的出台也紧锣密鼓地编制并发布。随着城市精细化治理在疫情大环境影响下呈现出的新需求、新场景的逐步广泛深入,政府在“六保”“六稳”的重点工作中提供积极有效的财政政策也给智慧城市各行业带来了新发展、新机遇。智慧城市在一个市域县域涉及到多个委办局管理部门,本文将解读智慧教育行业“十四五”期间出台的相关政策来洞察安防技术应用在该行业的未来发展前景。智慧城市如何“适度超前”布局新基建?
当前,我国经济发展面临重大的考验,既要统筹好疫情防控和生产经营工作,又要保障城市的平稳运行。作为稳定经济增长的“压舱石”,开展适度超前的基础设施建设尤为重要。5月17日,工信部负责人在2022年世界电信和信息社会日大会上透露,下一步将“适度超前”加快基础设施建设,推进数字基础设施助力智能交通、智能电网、智慧水利、智慧城市等建设发展,构筑融合发展坚实支撑。 事实上,从去年开始,政府就