华为交换下误接TP-LINK导致监控画面蓝屏的解决方案
1,问题描述
客户在监控网络中私自接了一台TP-LINK,TP-LINK频繁的向上游交换机发送TCN BPDU,导致每过一段时间网络监控系统就出现一次蓝屏或者闪断等现象;
S3700版本为:V100R006C05
< BL-1F-SZ-10.17>dis ver
Huawei Versatile Routing Platform Software
VRP (R) software, Version 5.70 (S3700 V100R006C05)
Copyright (C) 2003-2013 HUAWEI TECH CO., LTD
Quidway S3700-28TP-EI-AC Routing Switch uptime is 0 week, 2 days, 2 hours, 55 minutes
EOFEA 0(Master) : uptime is 0 week, 2 days, 2 hours, 54 minutes
128M bytes DDR Memory
16M bytes FLASH
Pcb Version : VER B
Basic BOOTROM Version : 349 Compiled at Mar 15 2013, 11:00:55
Software Version : VRP (R) Software, Version 5.70 (V100R006C05)
图1-1组网拓扑
2,告警信息
监控系统蓝屏、闪断现象截图如下:
3,处理过程
1、监控系统出现蓝屏或者闪断时,立刻查看网络有无异常告警,结果在核心交换机上发现如下告警信息:
<HX-S12708>dis trapbuffer
#Jan 13 2016 13:22:50 HX-S12708 MSTP/4/TCGUARD:OID 1.3.6.1.4.1.2011.5.25.42.4.2.15 The instance received TC message exceeded the threshold will be deferred to deal with at the end of TC protection time. (InstanceID=0)
2、通过上述信息初步怀疑是网络 STP震荡,然后在核心交换机上查看STP-BPDU统计信息如下:
<HX-S12708>display stp tc-bpdu statistics
-------------------------- STP TC/TCN information --------------------------
MSTID Port TC(Send/Receive) TCN(Send/Receive)
0 XGigabitEthernet1/3/0/0 1006/0 0/0
0 XGigabitEthernet1/3/0/1 771/0 0/0
0 GigabitEthernet1/2/1/1 209/0 0/0
0 GigabitEthernet1/2/1/4 218/0 0/0
0 GigabitEthernet1/2/1/5 244/0 0/0
0 GigabitEthernet1/1/1/1 225/0 0/0
0 GigabitEthernet1/1/1/3 212/0 0/0
0 GigabitEthernet1/1/1/4 239/0 0/0
0 GigabitEthernet1/1/1/5 256/0 0/0
0 GigabitEthernet1/1/1/6 218/0 0/0
0 GigabitEthernet1/1/1/7 233/0 0/0
0 XGigabitEthernet2/3/0/0 985/0 0/0
0 XGigabitEthernet2/3/0/1 1022/0 0/0
0 GigabitEthernet2/1/1/0 225/0 0/0
0 GigabitEthernet2/2/1/2 254/0 0/0
0 GigabitEthernet2/2/1/3 218/0 0/0
0 Eth-Trunk1 768/4 0/0
0 Eth-Trunk2 799/3 0/0
0 Eth-Trunk3 819/7 0/0
0 Eth-Trunk4 31/661 0/0
0 Eth-Trunk5 879/10 0/0
0 Eth-Trunk6 907/3 0/0
0 Eth-Trunk7 979/0 0/0
在核心S12708上查看stp拓扑改变,最近一次是10分钟之前,也是从Eth-Trunk4收到的。
<HX-S12708>display stp topology-change
CIST topology change information
Number of topology changes :443
Time since last topology change :0 days 0h:10m:18s
Topology change initiator(notified) :Eth-Trunk4
Topology change last received from :845b-1236-5090
Number of generated topologychange traps : 96
Number of suppressed topologychange traps: 59
3、然后登录到核心S12708的Eth-Trunk4口下接汇聚交换机<BLSZ-HJ-10.7>上查看stp tc-bpdu统计,GigabitEthernet0/0/2口收到的TC报文最多。
<BLSZ-HJ-10.7>display stp tc-bpdu statistics
-------------------------- STP TC/TCN information --------------------------
MSTID Port TC(Send/Receive) TCN(Send/Receive)
0 GigabitEthernet0/0/1 534/0 0/0
0 GigabitEthernet0/0/2 21/324 0/0
0 GigabitEthernet0/0/3 569/0 0/0
0 GigabitEthernet0/0/4 588/0 0/0
0 GigabitEthernet0/0/5 607/0 0/0
0 Eth-Trunk0 463/11 0/0
然后查看stp拓扑变更,最近一次拓扑改变也是GigabitEthernet0/0/2口。
<BLSZ-HJ-10.7>disp stp topology-change
CIST topology change information
Number of topology changes :385
Time since last topology change :0 days 0h:15m:23s
Topology change initiator(notified) :GigabitEthernet0/0/2
Topology change last received from :845b-1235-3ff0
Number of generated topologychange traps : 44
Number of suppressed topologychange traps: 14
4、在汇聚交换机<BLSZ-HJ-10.7>上找到GigabitEthernet0/0/2口下联交换机<BL-1F-SZ-10.17>,在<BL-1F-SZ-10.17>上查看stp tc-bpdu统计,发现Ethernet0/0/8口收到最多的TC报文。
<BL-1F-SZ-10.17>display stp tc-bpdu statistics
-------------------------- STP TC/TCN information --------------------------
MSTID Port TC(Send/Receive) TCN(Send/Receive)
0 Ethernet0/0/8 3362/911 6/256
0 Ethernet0/0/20 2218/0 0/0
0 GigabitEthernet0/0/1 1949/267 0/0
然后再查看stp拓扑变更,最近一次即是<BL-1F-SZ-10.17>的Ethernet0/0/8口。
<BL-1F-SZ-10.17>display stp topology-change
CIST topology change information
Number of topology changes :1435
Time since last topology change :0 days 0h:29m:55s
Topology change initiator(notified) :Ethernet0/0/8
Topology change last received from :0019-e8da-d088
5、查看Ethernet0/0/8口配置,发现是个边缘端口,配置如下:
interface Ethernet0/0/8
port link-type access
port default vlan 15
stp edged-port enable
6、询问客户Ethernet0/0/8下接的是什么设备,经过客户确认是他们最近自己私自接的一台TP-LINK交换机,用于其他业务。然后和客户协调关闭该接口观察一段时间,发现关闭接口后一切正常,问题没有复现。
4,根因
监控网络中私接的一台TP-LINK频繁的向上游交换机发送TCN BPDU,导致每过一段时间网络监控系统就出现一次蓝屏或者闪断等现象
5,解决方案
1.当网络中出现故障,多分析告警信息,通过display trapbuffer,display logbuffer等。
2.规范网络配置,shutdown没有使用的端口,可以有效避免私接交换机导致的网络故障。
6,建议与总结
在原有的网络中新接入其它设备应该充分考虑对现网的影响,有的时候多插了一根网线就会导致网络出现环路,导致网络瘫痪。另外,工程师服务完后一些注意事项应该和客户说明。
随机图文
-
主音响系统的功率分配(重要)
主音响系统的功率分配 扩声用主音箱系统的功率分配应根据所确定的组合台数,依照功率放大器不失真功率条件,选择适当的台数。对于音箱的驱动,可以采用前级分频方式,也可以采用功率分频方式。 为了保证厅堂内音箱系统工作的合理性与可靠性,在功率分配的分组与布线技术上,须作专门处理。 在大型厅堂,为了使音箱系统 -
2022年高新技术企业想投标,申请资质需要做什么准备?
国家高新技术企业一直以来都备受企业青睐,因为国家政策扶持力度很大。但是不要以为国家高企认定公示了就万事大吉,如果15天的公示期内被人提异议,很可能会被直接取消! 目前而言,无论是《行政许可法》亦或是《认定办法》及《工作指引》,均没有对取消高新技术企业资格的立案、调查取证、调 -
大神整理:招投标中的 100 种常见违规行为!
招标人与投标人 1.供应商直接或者间接从采购人或者采购代理机构处获得其他供应商的相关情况并修改其投标文件或者响应文件。 2.供应商按照采购人或者采购代理机构的授意撤换、修改投标文件或者响应文件。 3.招标人或采购代理机构编制的招标公告、资格审查文件以及招标文件等为特定投标人“量身定做”。 4.招标人招标 -
第七批“可信区块链系列评测”开启报名
区块链作为新型信息技术,不同系统在产品化程度、安全性、扩展性等方面表现各异。通过对区块链相关产品多维深度的评测,能够及时发现产品不足并强化其技术可靠性、功能完备性、安全可信性,进而解决区块链相关应用因底层系统质量问题导致项目可持续性不强、重复建设等问题。 “可信区块链系列评测”简介 “可信区块链系列评测”作为行业领先的区块链评测体系,由中国